Operation caution, Ventilator operation – Bloomfield Wells WVOC-2HFG User Manual

Page 15

Advertising
background image

OPERATION

CAUTION:

HOT SURFACE

Exposed surfaces can be hot
to the touch and may cause
burns.

VENTILATOR OPERATION


1. Press the VENTILATOR POWER switch to ON. The green

VENTILATOR POWER light will glow and the blower fan will start.

After a short time, if all filters are sensed as being in position and

not clogged, the cooking appliance will be energized.

During normal operation, the VENTILATOR POWER light will be

the only light glowing on the upper control panel.


2. If the amber CHECK FILTER light glows, one or more filter

elements is out of position. Check the GREASE BAFFLE,

PRE-FILTER and FILTER PACK for proper installation in their

respective positions. Grease baffle and filter pack position are

sensed by mechanical switches. Pre-filter position is sensed by a

vacuum

switch.


3. When the amber REPLACE PRE-FILTER light glows, the pre-filter

is nearing the end of its service life. Replace the disposable

PRE-FILTER

ELEMENT.


4. When the amber REPLACE FILTER PACK light illuminates, the

HEPA / Charcoal filter pack is nearing the end of its service life.

Replace the FILTER PACK.


Note: The REPLACE PRE-FILTER and REPLACE FILTER PACK

lights are a warning that the indicated filter is near the end of its

service life. The appliance will continue to operate for a period of

time after the light glows to allow continued operation through a

peak period. However, the indicated filters must be replaced within

a reasonably short time period or they will clog and shut down

electrical power to the cooking appliance . The ventilator blower

will continue to run.


5. When the red SERVICE REQUIRED light glows, either the

pre-filter or filter pack (or both) is clogged and can no longer pass

sufficient air to allow further operation. The ventilator fan continues

to run, but the cooking appliance is shut down until the underlying

clogged filter situation has been corrected. This can occur when

neither

CHANGE...FILTER indicator light is lit, if both pre-filter and

filter pack are marginal. Replacing both the pre-filter and the filter

pack will remedy the situation.


Note:

Replacing the pre-filter, even though not very dirty, will often

extend the service life of the more expensive filter pack.


Reset the unit by turning the VENTILATOR POWER switch to

OFF, then back ON.


6. A failure of incoming electrical power will cause a shut down of the

unit. After power is restored, reset the unit by turning the

VENTILATOR POWER switch to OFF, then back ON.


NOTE: Oven, griddle and hotplate will not operate unless the fire
suppression system is charged, and the ventilator section is operating .

Fig. 9 Ventilator Indicator

and

Warning

Lights

13

505

304963

Rev. (

-)

OpM

anual

W

V

O

C

-2HG

Advertising