Wiring diagram, Warning – Best WPD28I User Manual

Page 11

Advertising
background image

- 11 -

14. WIRING DIAGRAM

WARNING

Risk of electrical shocks. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.

!

LIGHT SOCKET

LIGHTS

SWITCH

FAN SWITCH

LIGHT SOCKET

Neutral

Line

W

W

W

Y

Y

Y

HS

THERMOSTAT

W

W

BK

BK

BK

BK

BK

BN

BN

SPEED CONTROL

BK

O

O

O

O

R

R

BK

BK

BK

W

W

BK

FIELD WIRING

BOX

W

W

W

W

O

W

BK

120 V Supply

Ground

O

W

BK

3

(16 AWG)

M

BLOWER

BK

HE0051A

WIRING COLOR CODE

BK

BLACK

G

GREEN

BN

BROWN

R

RED

W

WHITE

Y

YELLOW

1. If any of the original wire, as
supplied, must be replaced, use the
same equivalent wire.

2. Field wiring must comply with
applicable codes, ordinances and
regulations.

NOTES

G

W

LIGHT SOCKET

W

W

Y

W

W

W

LIGHT SOCKET

W

Y

W

W

W

W

W

Y

Y

W

For 48” width range hood only.

O

ORANGE

Advertising