Install ductwork, Warning – Best WPD28I User Manual

Page 4

Advertising
background image

- 4 -

1. INSTALL DUCTWORK

This exhaust hood is designed for use with gas or electric outdoor cooking appliances when operated in an outdoor
covered patio or lanai area. As with all electrical appliances, this unit should be protected from the effects of weather
as much as possible.

The

Best WPD28I model must be installed with the interior blower P12D only (sold separately). Other blowers cannot

be substituted.

Plan where and how the ductwork will be installed.

Install 10” round galvanized steel ductwork, elbows and roof or wall cap for the type of blower you are installing. Use
2” duct tape to seal duct joints.

The minimum hood distance above cooktop must not be less than 30”. A maximum of 36” above cooktop is
highly recommended for best capture of cooking impurities.

Run power cable to installation location.

ROOF CAP

30" TO 36" ABOVE

COOKING SURFACE

16

5

/

16

" to

TOP OF WOOD
MOUNTING STRIP

HOOD

OPTIONAL

DECORATIVE

FLUE or SOFFIT

10" ROUND DUCT

9" x 18" to 10"
ROUND TRANSITION
INCLUDED

18"

HH0022A

18"

WALL CAP

30" TO 36" ABOVE

COOKING SURFACE

16

5

/

16

" to

TOP OF WOOD

MOUNTING-STRIP

HOOD

OPTIONAL

DECORATIVE

FLUE or SOFFIT

9" x 18" to 10" ROUND

TRANSITION INCLUDED

HH0023A

WARNING

This unit is not designed for use with a charcoal grill.

!

WARNING

The power cable must be a GFCI protected branch circuit.

!

Advertising