Step 2b: attach casters, Step 3: connect to adjoining fryer sections, Step 4: connect electricity – Blodgett B24C-FF User Manual

Page 13: Step 5: check the installation

Advertising
background image

S

ECTIONAL

F

RYER

F

ILTER

S

YSTEM

I

NSTALLATION

O

WNER

S

M

ANUAL

1184960 P

AGE

13

OF

20

S

TEP

2

B

:

A

TTACH

C

ASTERS

NOTICE

For an appliance equipped with casters, (1) the installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances,
CAN/CGA-6.16,
and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for
Use With Gas Fuel, ANSI Z21.41,
or Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9, (2) adequate
means must be provided to limit the movement of the appliance without depending on the connector and the
quick-disconnect device or its associated piping to limit the appliance movement and (3) the restraining means
should be attached to a frame member on the back of the unit.

A set of four casters is packed with appliances ordered with casters (instead of legs).
A threaded leg pad is fastened to the base frame at each corner. Each caster has a corresponding mating thread. The
casters can be adjusted to overcome a slightly uneven floor. Casters are provided with a Zerk fitting for proper
lubrication when required.

1. Raise the appliance sufficiently to allow the casters to be attached. For safety, “shore up” and support the

appliance with an adequate blocking arrangement strong enough to support the load.

2. Screw the casters into the holes in the centers of the leg pads. Install the casters that have a locking brake under

the front of the appliance.

3. Lower the appliance gently onto a level surface. Never drop or allow the appliance to fall.

NOTICE

Adequate means must be provided to limit the movement of the appliance without depending on the connector and
the quick-disconnect device or its associated piping to limit the appliance movement.

The restraining means should be attached to a frame member on the back of the unit.

S

TEP

3:

C

ONNECT TO

A

DJOINING

F

RYER

S

ECTIONS

Follow the battery connection procedure described in the manual(s) for the adjoining section(s) of the battery.
Custom assembly instructions for the internal piping of the oil drain piping from the adjoining fryer(s) to the Sectional
Fryer Filter System cabinet will be furnished with each individual battery.

CAUTION

ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE ONLY
SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE APPLIANCE HAS BEEN PUT INTO
OPERATION. TEST PRESSURE SHOULD NOT EXCEED 14" W.C.

S

TEP

4:

C

ONNECT

E

LECTRICITY

Be sure that the input voltage and phase match the requirements shown on the serial plate.
Appliances ordered with a 115V, 60Hz, single-phase electrical rating are factory-supplied with a three-wire cord with
a three-prong plug that fits any standard three-prong grounded receptacle. Plug the cord into a grounded outlet able
to supply at least 6.2 amperes.
Appliances ordered with a 230V, 60Hz, single-phase electrical rating are factory-equipped with a terminal block.
Connect the appliance to a power source able to supply at least 2.6 amperes.

S

TEP

5:

C

HECK THE

I

NSTALLATION

1. Check that all screws and bolts are tightened.
2. Check that the gas connection has been made correctly.
3. Check that the electrical connection has been made correctly, and verify that the electrical characteristics of the

electric power source match the appliance.