1184960 P

AGE

5

OF

20

G

AS

S

UPPLY

The Sectional Fryer Filter System does not use any gas, but it does have a 1-1/4" front gas manifold the couples to
the adjacent sectional unit(s).

E

LECTRICITY

S

UPPLY

The Sectional Fryer Filter System requires electric power (50Hz or 60Hz single-phase AC). 120V models draw a
maximum of 6.5 amps, and have a 7-foot (2134 mm) power cord with a grounded plug. 230V models draw a
maximum of 2.6 amps, and have a terminal block for connection to a single-phase 230V source.
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as
applicable.

V

ENTILATION

WARNING

Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove flue products
can cause headaches, drowsiness, nausea, or could result in death.

All gas appliances must be installed in such a manner that the flow of combustion and ventilation air is not
obstructed. Provisions for adequate air supply must be provided.

NOTICE

Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the
warranty.

Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s
instructions.

The Sectional Fryer Filter System is electrically powered, and so does not require combustion air. However, the flue
riser may contain exhaust gasses from adjoining appliances that share an optional continuous flue riser. Follow the
ventilation requirements for the adjoining section(s).