O

PERATION

S

ECTIONAL

F

RYER

F

ILTER

S

YSTEM

P

AGE

6

OF

20 O

WNER

S

M

ANUAL

1184960

O

PERATION

DANGER

EXPLOSION HAZARD

In the event a gas odor is detected, shut down equipment at the main shut off valve. Immediately call the
emergency phone number of your gas supplier.

WARNING

BURN HAZARD

CONTACT WITH HOT OIL WILL CAUSE SEVERE BURNS. ALWAYS USE CAUTION. OIL AT 200°F IS MORE
DANGEROUS THAN BOILING WATER.

The fryer filter system is contained in a cabinet that is part of a battery that includes deep fryers (see Figure 3). The
frypot-drains of the fryers are connected to a pipe that drains into a filter pan in the bottom of the filter cabinet. When
the power switch of the filter system is turned on, a pump draws the drained oil through a filter on the bottom of the
filter pan to remove breading and other impurities, and pumps the oil out of a discharge hose. The discharge hose can
be positioned to return the filtered oil to a frypot, to pump it into a container for disposal, or to pump it into a container
for storage while the frypot is cleaned.

Figure 3

Fryer Filter System Operation

Filter Discharge Hose

Fryer Drain Pipe

Drain Pan

(Cabinet Doors Not Shown)