Bunn H5M User Manual

Page 14

Advertising
background image

14

FIG. 10 THERMOSTAT WIRING

BLU/BLK to Limit Thermostat

BLK to Terminal Block

P1782

SERVICE (cont.)

Thermostat
Location: The mechanical thermostat is located inside
the upper rear panel. To test the thermostat, access
will also be needed to the terminal block located inside
the bottom access panel.

Test Procedure:
1. Disconnect the dispenser from the power source.
2. Check the voltage across the black wire on the ther-

mostat and the white or red wire at the terminal
block with a voltmeter. Connect the dispenser to

Advertising