Aintenance and care replace drive belt, Clearing a clog – Bissell Powerforce HELIX 12B1 series User Manual

Page 11

Advertising
background image

11

M

aintenance and Care

Replace drive belt

1.

Turn power OFF. Unplug vacuum cord from

electrical outlet.

2.

With rotating brush removed (steps 1-4

of Check rotating floor brush and drive

belt), grasp old drive belt and remove from

motor pulley. Discard old drive belt.

3.

Place new drive belt over motor pulley and

stretch other end over rotating floor brush

in the space between the bristles. Place

ends of rotating floor brush down into

slots.

4.

Turn rotating floor brush by hand in the

direction of the motor pulley. If properly

installed, drive belt will center itself on

rotating brush.

5.

Reposition brush cover and fasten four

screws back into place.

Clearing a Clog

Low suction or poor pickup may be due

to a clog in the vacuum. If you notice

a change in the sound of the vacuum

motor, check for clogs.

1.

Turn power OFF. Unplug vacuum cord from

electrical outlet.

2.

Empty Dirt Container.

3.

Check upper tank and suction inlet

for clogs.

4.

Grasp Quick Reach handle and remove

hose wand from base to check for clogs in

the base, the wand, and the hose.

5.

Remove the screw attaching the hose wand

base to the vacuum. Straighten the hose

wand base and unclog, with long, narrow

object such as broom stick.

6.

If the clog persists, follow steps for

checking rotating floor brush on page

10 and inspect the air passageway for

obstructions.

3

5

Advertising