Time Server

The VideoJet X40 can receive the time signal from a time server using various time server

protocols, and then use it to set the internal clock. The unit polls the time signal automatically

once every minute.

5.9.1

Unit time zone

Select the time zone in which your system is located.

5.9.2

Daylight saving time

The internal clock can switch automatically between normal and daylight saving time (DST).

The unit already contains the data for DST switch-overs up to the year 2015. You can use

these data or create alternative time saving data if required.

1.

First check whether the correct time zone is selected. If it is not correct, select the

appropriate time zone for the system, and click the Set button.

2.

Click the Details button. A new window will open and you will see the empty table.

3.

Select the region or the city which is closest to the system's location from the list field

below the table.

4.

Click the Generate button to generate data from the database in the unit and enter it into

the table.

5.

Make changes by clicking an entry in the table. The entry is selected.

6.

Clicking the Delete button will remove the entry from the table.

7.

Select other values from the list fields below the table to change the entry. Changes are

made immediately.

8.

If there are empty lines at the bottom of the table, for example after deletions, you can

add new data by marking the row and selecting required values from the list fields.

9.

Now click the OK button to save and activate the table.

5.9.3

Time server IP address

Enter the IP address of a time server.

5.9.4

Time server type

Select the protocol that is supported by the selected time server. Preferably, you should

select the SNTP server as the protocol. This supports a high level of accuracy and is required

for special applications and subsequent function extensions.

Select Time server for a time server that works with the protocol RFC 868.

i

NOTICE!

If you do not create a table, there will be no automatic switching. When changing and clearing

individual entries, remember that two entries are usually related to each other and dependent

on one another (switching to summer time and back to normal time).