en | Configuration Using a Web Browser

VideoJet X40

V3.5 | 2007.12

Installation and Operating Manual

Bosch Security Systems

5.23.11

Scene too bright

Activate this function if tampering associated with exposure to extreme light (for instance,

shining a flashlight directly on the lens) should trigger an alarm. The average brightness of the

scene provides a basis for recognition.

5.23.12

Scene too dark

Activate this function if tampering associated with covering the lens (for instance, by spraying

paint on it) should trigger an alarm. The average brightness of the scene provides a basis for

recognition.

5.23.13

Scene too noisy

Activate this function if tampering associated with EMC interference (noisy scene as the result

of a strong interference signal in the vicinity of the video lines), as an example, should trigger

an alarm.

5.23.14

Global change

Activate this function if the global change, as set with the Global change slide control, should

trigger an alarm.

5.23.15

Reference check

You can save a reference image that is continuously compared with the current video image. If

the current video image in the marked areas differs from the reference image, an alarm is

triggered. This allows you to detect tampering that would otherwise not be detected, for

example if the camera is turned.

1.

Click Reference to save the currently visible video image as a reference.

2.

Click Select area and select the areas in the reference image that are to be monitored.

3.

Check the Reference check box to activate on-going matching. The stored reference

image is displayed in black and white below the current video image, and the selected

areas are marked in yellow.

5.23.16

Select area

You can select the image areas in the reference image that are to be monitored. The video

image is subdivided into 858 square fields. Each of these fields can be activated or

deactivated individually.

1.

Click Select area to configure the sensor fields. A new window will open.

2.

If necessary, click Clear all first to clear the current selection (fields marked yellow).

3.

Left-click the fields to be activated. Activated fields are marked yellow.

4.

If necessary, click Select all to select the entire video frame for monitoring.

5.

Right-click any fields you wish to deactivate.

6.

Click OK to save the configuration.

7.

Click the close button X in the window title bar to close the window without saving the

changes.

i

NOTICE!

Select only those areas for reference monitoring in which no movement takes place and that

are always evenly lit, as false alarms could otherwise be triggered.

Advertising