26 relay settings, Relay settings – Bosch VIDEOJET X40 User Manual

Page 72

Advertising
background image

72

en | Configuration Using a Web Browser

VideoJet X40

V3.5 | 2007.12

Installation and Operating Manual

Bosch Security Systems

5.26

Relay Settings

You can configure the switching behavior of the relay outputs. For each relay, you can specify

an open switch relay (normally closed contact) or a closed switch relay (normally open

contact).

You can also specify whether an output should operate as a bistable or monostable relay. In

bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set

the time after which the relay will return to the idle state.

You can select different events that automatically activate an output. It is possible, for

example, to turn on a floodlight by triggering a motion alarm and then turning the light off

again when the alarm has stopped.

5.26.1

Idle state

Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is

to operate as an NC contact.

5.26.2

Operating mode

Select an operating mode for the relay.

For example, if you want an alarm-activated lamp to stay on after the alarm ends, select

Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select

10 s.

Advertising