Hale MG User Manual

Page 108

Advertising
background image



Muscle Pumps

5-44


17) Attach hoses or tubing to inlet

fittings of the drain valve.


18) Test operate apparatus and check

drain valve for leaks.


19) Return apparatus to normal

operation.


c. Type DV7 Drain Valve:

(Refer to figure 6-23)


If the type DV7 drain valve is leaking
the seals must be replaced. Replace
the seals using the following
procedures:


1) Place apparatus out of service in

accordance with department
procedures.


2) Open all drain valves to make

sure all pressure is relieved from
the pump.


3) Gain access to the backside of the

valve body where the grease
fitting is located. Remove any
tubing or hoses that interfere with
valve disassembly. Remove the
retaining ring from the valve
stem.

4) Unscrew the valve stem

completely from the valve body.

5) Remove the retaining ring that

holds the seat and seat retaining
washer on the valve stem.

6) Remove the seat retaining washer

from the stem with the thrust
washers.


7) Remove the seat from the seat

retaining washer.

8) Remove the knob from the stem

by loosening the set screw in the
knob.

9) Clean all parts and check for

excessive wear or pitting. Check
to make sure the sealing surfaces
of the inlet fittings are clean and
not pitted.


10) Install a new seat in the seat

retaining washer.


11) Install a thrust washer on the stem

then install the seat retaining
washer and the other thrust
washer. Secure these parts to the
stem using the retaining ring.


12) Install the operating knob on the

stem and secure in place with the
setscrew.


13) Carefully thread the stem assembly

into the valve body.


14 Lock the stem assembly in the

body using the retaining ring.


15) Attach hoses or tubing to inlet

fittings of the drain valve.


16) Test operate apparatus and check

drain valve for leaks.


17) Return apparatus to normal

operation.

Advertising