Owner’s manual, Compressor (cont’d) maintenance (cont’d) – Steele Products SP-CE355AT User Manual

Page 24

Advertising
background image

24

Owner’s Manual

Compressor (cont’d)

MAINTENANCE (cont’d)

Relieve the air pressure in the system and open the petcock on the
bottom of the tank to drain.

WARNING! CONDENSATION WILL ACCUMULATE IN THE TANK. TO

PREVENT CORROSION OF THE TANK FROM THE INSIDE, THIS MOISTURE
MUST BE DRAINED AT THE END OF EVERY WORKDAY, BE SURE TO WEAR
PROTECTIVE EYE WEAR.

Note: In cold climates, drain the tank after each use to reduce problems with

freezing of water condensation.

Testing for Leaks
Check that all connections are right. A small leak in any of the hoses or pipe
connections will substantially reduce the performance of your air compressor. If you
suspect a leak, spray a small amount of soapy water with spray bottle. If bubbles
appear, repair or replace the faulty component. Do not over tighten any connections.
Storage
Before storing the compressor for a prolonged period, use an air blow gun to clean all
dust and debris from the STORAGE compressor. Disconnect the power cord and coil
it up. Pull the pressure relief valve, release all pressure from the tank. Drain all moisture
from the tank. Cover the entire unit to protect it from moisture and dust.
Servicing
Perform the following maintenance at the intervals indicated below:
• Operate the pressure relief valve:

Daily

• Drain air from tank:

Daily

• Change oil every 300 hours.