Troubleshooting – Steele Products SP-WE180 User Manual

Page 16

Advertising
background image

16

Problem

Possible Cause

Correction

Motor will not start

or stops while

operating

Circuit breaker

tripped or fuse blown

in circuit fuse box

Disconnect all other loads on the same

circuit and reset circuit breaker or

replace fuse

Loose or discon-

nected plug

Reconnect plug

Tripped pressure

washer circuit

breaker

Allow to cool and restart unit

Circuit breaker trips

or fuse

blown in fuse box

Circuit overload

Check that circuit is rated 15 A or greater.

Disconnect all loads on the circuit

Extension cord too

long or wire size

Use proper extension cord as

recommended in Operator’s Manual

Nozzle partially

blocked

Clean nozzle as instructed

Water or oil leaking

from

bottom of pump

A small amount of

leakage is normal

If excessive leaking occurs call

Customer Service Department

Pressure increases

when

gun is closed

Bypass valve not op- Call Customer Service Department

erating properly

Motor running but

pump not building

maximum pressure

or has irregular

pressure

Faucet closed

Open faucet.

Unit has been stored

in freezing

temperature

Thaw out unit completely including

hose, gun and wand

Troubleshooting