Service instructions, Maintenance instructions, General – L.B. White I-40 Infraconic Ignition User Manual

Page 14

Advertising
background image

1. Close the fuel supply valve to the heater before

servicing unless it is necessary to have it open for

your service procedure.

2. For reassembly, reverse the respective service

procedure. Ensure gas connections are tightened

securely.

3. After servicing, start the heater to ensure proper

operation and check for gas leaks.

4. CClleeaann tthhee hheeaatteerr’’ss oorriiffiicceess wwiitthh ccoom

mpprreesssseedd aaiirr oorr aa

ssoofftt,, ddrryy rraagg.. DDoo nnoott uussee ffiilleess,, ddrriillllss,, bbrrooaacchheess,, eettcc.. ttoo

cclleeaann tthhee oorriiffiiccee hhoolleess.. DDooiinngg ssoo wwiillll eennllaarrggee tthhee hhoollee,,

ccaauussiinngg ccoom

mbbuussttiioonn oorr iiggnniittiioonn pprroobblleem

mss.. RReeppllaaccee

tthhee oorriiffiiccee iiff iitt ccaannnnoott bbee cclleeaanneedd pprrooppeerrllyy..

1144

Service Instructions

GENERAL

W

WAARRNNIINNGG

FFiirree aanndd EExxpplloossiioonn HHaazzaarrdd

Do not disassemble or attempt to repair any heater

components or gas train components.

All component parts must be replaced if defects are

found.

Failure to follow this warning will result in fire or

explosions, causing property damage, injury, or death.

1. Have your gas supplier check all gas piping annually

for leaks or restrictions in gas lines. Also, at this time

have your gas supplier clean out the sediment trap on

the zone control panel of any debris that may have

accumulated.

2. TThhee hheeaatteerr’’ss ssuurrrroouunnddiinngg aarreeaa sshhaallll bbee kkeepptt cclleeaarr aanndd

ffrreeee ffrroom

m ccoom

mbbuussttiibbllee m

maatteerriiaallss,, ggaassoolliinnee,, aanndd ootthheerr

ffllaam

mm

maabbllee vvaappoorrss aanndd lliiqquuiiddss..

3. Regulators can wear out and function improperly.

Have your gas supplier check the date codes on all

regulators installed and check delivery pressures to

the appliance to make sure that the regulator is

suitable for continued use.

4. Regulators must be periodically inspected to make

sure the regulator vents are not blocked. Debris,

insects, insect nests, snow, or ice on a regulator can

block vents and cause excess pressure at the

appliance.

5. For safety as well as for optimum performance at the

heater, it is necessary to keep the inside and the

outside of the heater free of dust, dirt or any

combustible material. If any operational component

shows signs of rust or corrosion, replace the

component immediately.

6. If any warning or instruction labels, dataplates, etc.

become lost or hard to read, replace them

immediately. Do not operate the heater until you

have all instructions and can read and understand

them.

7. Check overall condition of heater for cracked or

damaged components, loose screws or bolts, etc.

Replace any suspect components.

8. Check all hose and tubing assemblies for cracks,

abrasions or ruptures. Replace any hoses that are

suspect.

If it becomes apparent that a dark spot has formed part way

up on the inner combustion cone or a build up of debris is

occurring in the bottom of the inner cone, it will be

necessary to clean out the combustion cone assembly.

Refer to “Cleaning Instructions”.

Maintenance Instructions

W

WAARRNNIINNGG

BBuurrnn HHaazzaarrdd

Heater surfaces are extrememly hot for a period of

time after the heater has been shut down.

Allow the heater to cool before performing service,

maintenance, or cleaning.

Failure to follow this warning will result in burns

causing injury.

Advertising