Power supply


220-240 VOLTAGE: The Galileo Mixer must be connected to a voltage of 220 - 240 Volt (or otherwise specified following
local situations), which has a differential (MINIMUM 30mA), a magnetothermic protection of 16 Amp and a grounded outlet
according to local regulations.
115 VOLTAGE: The Galileo Mixer must be connected to a voltage of 115 Volt (or otherwise specified following local
situations), which has a differential (MINIMUM 30mA), a magnetothermic protection of 25 Amp and a grounded outlet
according to local regulations.

THE ACCESS TO THE ELECTRICAL WIRING IS ALLOWED TO SKILLED PEOPLE ONLY.

DON’T WORK WITH THE MACHINE IF BACK PANEL IS OFF.

Safe use of the machine


The manufacturer has adopted all measures and attentions projecting, drawing manufacturing , checking , installing ,
starting and defining the procedures for using its products, to guarantee the highest possible level during a rational use of
the supplied system. The components are in conformity to the recent security rules. Updated security equipments are
installed to assure the maximum security level that it is available today.
When using the FAST & FLUID MANAGEMENT Galileo Mixer, the following safety regulations need to be observed:
The "user" is expected to follow all local safety regulations. If there is a contradiction in European regulations and local
regulations, the demands of the most severe legislation must be met.

The installation and the maintenance of the Galileo Mixer

have to be performed by a specialized technician

Service safety rules

1. To prevent any physical injuries all outside panels should always be in place on the Galileo Mixer and properly

secured.

2. Don’t touch protections system as speed control and blocking security closing door.
3. Prior to any maintenance and inspection of the Galileo Mixer: disconnect the power cord from the outlet mains. Make

sure that the Galileo Mixer cannot be started unexpectedly.

4. Do not leave any tools inside in the Galileo Mixer after maintenance.
5. Check that the environment where the machine is installed conforms to local regulations (a permit issued by the fire

marshall or by local autority may be necessary) and avoid dangerous concentration of paint cans around the
equipment. It’s forbidden to stock inflammable materials or other materials inside the machine. It’s forbidden to use free
flames , incandescent objects or equipments able to create sparks in the local where the machine is installed.

6. It is recommended to install a ventilation system to guarantee that the concentration of dangerous vapours around all

electrical components is less than 30%.

7. At the end of the work avoid to keep free cans inside the machine and avoid to keep the machine switched on if it isn’t

used.

8. If the machine is switched on but it isn’t stirring inside it, there isn’t residual energy because the inverter is switched off.
9. In the locations where the Mixer Galileo is installed the prohibition symbols “no smoking” have to be present placed at 5

meters from the machine.

This equipment was built for the treatment of not explosive materials. It’ is forbidden to use

this machine with flammable or explosive vapours.

Warning:

Avoid to operate the Galileo Mixer without a clamped load.

Never use a load with a weight over 35 Kg.

Don’t switch-off the machine with the can inside.

Do not place any damaged packaging in the Galileo Mixer.

Further rupture during mixing may cause damage to the Galileo Mixer

Running the Galileo Mixer with damaged packaging is at "User's" risk.

Already damaged packaging may cause damage to the your machine.

During the maintenance respect the security rules and the procedure described in its paragraph.

The Galileo Mixer is to be operated only by trained personnel. FAST & FLUID MANAGEMENT shall not be liable for

any damage or injury caused by non - compliance with the "user"- and "safety" - regulations presented in this manual,

or by not taking the usual and accepted precautions in handling, operation or repair, even if not expressly stated in

this manual.

This is also valid for damage and/or accidents as a result of changes made to the machine, that are implemented without

prior notice to and approval by FAST & FLUID MANAGEMENT.

Advertising