Check of the main transmission belt








Verify the tension of the belt which has
to have a bending of 5 ÷ 10 mm when
we push with finger the longer free part.

If necessary tension the belt by using
the bolt (mm 13) indicated

By using a belt tension tester (which
operates by measuring sound waves),
make sure that frequency of the vertical
transmission belt is about 90Hz, and that
frequency of horizontal transmission belt
is about 125Hz.

Verify that the belt hasn’t any grindings
while turning manually the central pulley

Assemble the back panel to its original
position.

 Make sure that there isn’t any

can in the basket

 Switch off the mixer Galileo

operating on the back rotating
switch

 Remove the back panel

unscrewing the 14 screws using
a screwdriver (PZ 2)




































ACTUATOR

CONTROL

BOARD









LOGIC BOARD









OPTICAL
SENSORS

BOARD










INVERTER BOARD

FILTER + CABLE