RECOMMENDED SCREW PLACEMENT TABLE

Details are subject to change without prior notice.

Note: If using treated lumber, special corrosive resistant screws are required. Ask your sales representative for more information.

Zone

FASTENER

SUBSTRATE

90

ON CENTER

SPACING

100

ON CENTER

SPACING

110

ON CENTER

SPACING

120

ON CENTER

SPACING

130

ON CENTER

SPACING

140

ON CENTER

SPACING

Zone 1

#12-11 X 1”

15/32” CDX

7/16” OSB

1x4 Wood Purlins

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

N/A

Type 1, 24”

42”

N/A

Type 1, 24”

42”

N/A

Type 1, 24”

Zone 2

#12-11 X 1”

15/32” CDX

7/16” OSB

1x4 Wood Purlins

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

15”

Type 1, 24”

42”

N/A

Type 1, 24”

36”

N/A

Type 1, 24”

12”

N/A

Type 2, 24”

Zone 3

#12-11 X 1”

15/32” CDX

7/16” OSB

1x4 Wood Purlins

42”

15”

Type 1, 24”

42”

15”

Type 1, 24”

12”

15”

Type 1, 24”

12”

N/A

Type 2, 24”

12”

N/A

Type 2, 24”

12”

N/A

Type 2, 24”

WIND SPEED ZONE

FASTENING SCHEDULE SPACING ALONG PANEL NAIL STRIP

With < 30’-0” mean roof height -

3:12 to 6:12 pitch

for 90-140 mph wind speeds based on ASCE 7-93

Zone

FASTENER

SUBSTRATE

90

ON CENTER

SPACING

100

ON CENTER

SPACING

110

ON CENTER

SPACING

120

ON CENTER

SPACING

130

ON CENTER

SPACING

140

ON CENTER

SPACING

Zone 1

#12-11 X 1”

15/32” CDX

7/16” OSB

1x4 Wood Purlins

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

15”

Type 1, 24”

Zone 2

#12-11 X 1”

15/32” CDX

7/16” OSB

1x4 Wood Purlins

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

15”

Type 1, 24”

42”

15”

Type 1, 24”

Zone 3

#12-11 X 1”

15/32” CDX

7/16” OSB

1x4 Wood Purlins

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

30”

Type 1, 24”

42”

15”

Type 1, 24”

42”

15”

Type 1, 24”

WIND SPEED ZONE

FASTENING SCHEDULE SPACING ALONG PANEL NAIL STRIP

With < 30’-0

"

mean roof height -

7:12 to 12:12 pitch

for 90-140 mph wind speeds based on ASCE 7-93

CORRUGATED PANEL