J.P. Instruments Fuel Scan 450M Pilots Guide User Manual

Page 15

Advertising
background image

For Your Safe Flight

Page 13

Setting the GPS-C Comm settings

The GPS-C setting selects the format of the fuel data output of the
FS-450M.

GPS-C

Input to GPS; output of FS-450M

0

No fuel data output

1 *

Garmin (Shadin Miniflow format)

2 *

Allied Signal (format B)

3

Arnav/EI fuel data

4

Allied Signal (format C)

5

(Not

used)

6 *

UPS fuel/air data

* Recommended formats.

FS-450M Set Up

Factory Default Set Up

The factory default fuel measurement units are gallons and the
alarm limits are 45 minutes for the low time alarm, and 10 gallons
for the low fuel alarm. The K-factor defaults are K=29.00
(29,000).

Changing the FS-450M Set Up

You may need to change the fuel measurement units, the fuel tank
capacity, and may prefer to set your own alarm limits. Follow the
procedure outlined below to change any of the factory default
settings.

To start the Set Up procedure, after power up, wait until the FS-
450M completes its self test and is in the Automatic or Manual
indexing mode. If in doubt, tap the STEP button a few times. Then
follow the steps illustrated below. The display will then sequence
as shown in the chart below. Tap the STEP button to advance to
the next item in the list. Tap the AUTO button to select alternate
values of that item. Hold AUTO button to increase a numerical
value; tap the AUTO button to decrease a numerical value.