To fine tune the %HP readout, follow this procedure airborne between
5,000 and 8,000 feet MSL.

1. Enter the pilot program mode by simultaneously holding the

STEP

and

LF

buttons for five seconds.

2. Tap

STEP

repeatedly until you see HP Constants. Hold both

NEXT

and Button 2 until you see ROP and LOP appear in status bar. Tap
ROP

.

Now HP Constant 125 should appear. Hold both

NEXT

and

Button 2 until you see ADJUST momentarily. Adjustment range for
the HP Constant is 50 to 300.

3. Set the MP and RPM per your POH to 70 percent power. Let

conditions stabilize.

4. Adjust the HP Constant value

PLUS

or

MINUS

so that the %HP

reading on the display equals ‘

70

%HP

’. Note: this is the percent of

maximum horsepower.

5. Hold both

NEXT

and Button 2 until you see SET.

Adjusting the MAP

This procedure allows you to adjust the MAP to the altimeter setting at a
sea level airport. NOTE: If airport is not at sea level, use the
correction table to derive corrected sea level altimeter setting).

1. Enter the pilot program mode by simultaneously holding the

STEP

and

LF

buttons for five seconds.

2. Tap

NEXT

repeatedly until you see MAP ADJUSTMENT +0.0.

Then hold both the

NEXT

and Button 2 until you see ADJUST

momentarily.

3.

Adjust the value using the

PLUS

or

MINUS

until the value equals the

altimeter setting (sea level airport). The adjustment range for the
MAP is ±3.0 inHg.

4. Hold both

NEXT

and Button 2 until you see SET.