J.P. Instruments EDM 960 Twin Pilots Guide User Manual

Page 44

Advertising
background image

For Your Safe Flight

Page 39

HP Constant

=

125

10

⇔999

Hold NEXT and button 2 until you see
ADJUST. Tap PLUS or MINUS to
adjust (%HP display will reflect
changes). Hold NEXT and button 2 to
save changes.

Engine Constant = 14.9

1

⇔ 99.9

Hold NEXT and button until you see
ADJUST. Tap PLUS or MINUS to
adjust. Hold NEXT and button 2 to
save changes.

Engine HP = 225

10

⇔999

Set the nominal horsepower of your
engine. This value will be multiplied by
the %HP to display HP. Hold NEXT
and button 2 for 5 seconds until you
see ADJUST. Use PLUS or MINUS to
adjust. Tap SAVE to save changes.
Tap NEXT to skip to next item.

Lft MAP

Rft MAP

-3.0

⇔+3.0

Correct the MAP to the altimeter
setting at a sea level airport ±3.0 inHg.
Hold NEXT and button 2 for 5 seconds
until you see ADJUST. Use PLUS or
MINUS to adjust. Tap SAVE to save
changes. Tap NEXT to skip to next
item.

Lft K-Factor 1= 29.90

Rht K-Factor 1= 29.90

00.10

99.99

Set the instrument’s K-factor to match
the fuel flow transducer K-factor and
performance. Hold NEXT and button 2
for 5 seconds until you see ADJUST.
Use DIGIT, PLUS or MINUS to adjust.
Hold NEXT and button 2 to save
changes.

GPS Format = 6

0

⇔ 8

Adjust to set the GPS Communications
format. Hold NEXT and button 2 for 5
seconds until you see ADJUST. Use
PLUS or MINUS to adjust. Tap SAVE
to save changes. Tap NEXT to skip to
next item.

Time: 18:23:59

00:00:00

23:59:59

Hold NEXT and button 2 for 5 seconds
until you see ADJUST. Use Hours,
Minutes, Seconds to adjust. Tap
SAVE to save changes. Tap NEXT to
skip to next item.

Advertising