Diagnostic Messages

The following displays indicate a malfunction in the system:

Startup and Operational Diagnostics

0.0 GPH

Zero’s indicate Fuel flow is too low to register

--- GPH

Dashes indicate No fuel flow transducer signals

--- H.M

Dashes indicate No fuel flow transducer signals

OPEN PRB

Open probe. Wiring to probe is open circuit. Check
wiring and crimps. Swap probes to troubleshoot.

BAD-PRB

Bad probe. Erratic reading. May be poor electrical
connection. Swap probes to troubleshoot.

Red ‘X’ drawn
through a single
gauge

Measurement out of range.

Red ‘X’ drawn
through all
gauges for an
engine

DAU failure or DAU communications error.
Check power to DAU and wiring harness
connections.

CAL ERR

Calibration error. Return unit to factory.

DSP XXX

Internal communication error. Return unit to factory.

COMM ERR

Internal communication error. Return unit to factory.

NO I 5 MV

Calibration error. Return unit to factory.

NO 50MV

Calibration error. Return unit to factory.

NO 2.5V

Calibration error. Return unit to factory.

PWR DWN

Power down the instrument and power up again.

WARNCAL,
WARNCFG

Transient warning messages. If they persistently occur,
return the unit to JPI for repair.

HOBSERR

The time of the most recent flight may not be reflected in
the HOBBS meter.

HOBSBAD

The HOBBS data has been corrupted. The HOBBS
meter will be cleared.

HANGCFG,
HANGCAL

Internal system errors. Return unit to factory.