Leanfind basics – J.P. Instruments EDM 960 Twin Pilots Guide User Manual

Page 9

Advertising
background image

For Your Safe Flight

Page 4

Scanner® Display Basics
The EDM Scanner section is located in the lower left area of the screen.
It consists of a graphical display of EGT and CHT (and TIT if so
equipped) and a digital display that automatically scans the various
parameters. You can select Manual Mode by tapping

STEP

to lock onto

the

parameter of interest. To return to Automatic scan mode, tap

LF

followed by tapping

STEP

.

LeanFind Basics

Simply pre-lean, tap the

LF

button (Lean Find) and begin
leaning. The EDM will assist
you in finding the first
cylinder to peak. This
example is for Rich of Peak.
See page 19 for a more detailed description of leaning.

1. Establish cruise at approximately 65 to 75% power and pre-lean the

mixture to 50°F estimated rich of peak EGT on any cylinder.

2. Wait about 30 seconds, then tap the

LF

button.

3. Begin leaning the mixture smoothly without stopping. Turn a vernier

about ¼ turn per second; retract a non-vernier or quadrant lever so
that EGT rises about 10°F per second.

4. Stop leaning when you see

LEANEST

for two seconds, followed

by—for example—

EGT

1520

FF

13.8. The EGT number is the current

temperature of the first EGT to peak and the FF number is the
current fuel flow.

5. Now tap the

PEAK

button to display the EGT difference from peak

which is very useful for setting desired degrees below peak.

6. Slowly enrich the mixture noting that the EGT difference diminishes

as EGT climbs back to peak, followed by it going minus again. Stop
enriching at the desired EGT difference (such as ‘

EGT

-75’).

7. You can also see what the peak EGT was by holding the

PEAK

button.

8. Tap

STEP

to exit the Lean Find Mode.

Advertising