FAA Approved Installation Manual for the EDM-960 system Report No 909

Primary Engine Data Management System Page 22 of 46 Rev D

Date 2-6-2014


29. Capturing the sender reading at each calibration point:

Getting Started…Collecting Fuel Level Calibration Data using the EDM as a meter.

1. For each EDM monitored tank, create a paper table with the desired number of calibration points (2 to 5) and at what

volume each will be. Number of calibration points to be entered into the system later. The zero gallon point reading is
always taken with unusable fuel in the tank. Example of a completed 3 point table for LEFT tank:

LEFT

F 39.0

GAL

1907

2 19.5

GAL

1154

E

0.0 GAL

685

2. This screen provides real-time readings of all active fuel level sensors. Verify readings look normal. Reading are arbitrary

whole numbers

3. Now add fuel as needed to match the required volume for a particular point. Allow this to settle, then take a reading and

record it on paper adjacent to that point.

4. Repeat this process until all points have been recorded for each tank.

Actual Screen Shot

29.1 After you have collected your data

After you have collected your data…Entering / Editing Fuel Level Calibration Data

The Fuel Table Editor is a spreadsheet type format allowing you to easily see the volume and related calibration values side by
side. You can easily navigate through the cells to enter values.

1. With power off, hold in Button

3 (Button 1 being far left) and then turn on power. Wait until you see ‘Do you agree

with the disclaimer?’. Tap YES if you agree and wish to continue.