Introduction

The Pro Series Pair of Pumps combination system
is designed to provide both primary and backup
pumping capabilities. The primary pump will
operate as long as it is receiving AC power. If
the power is interrupted, or more water is
coming into the sump than the AC pump can
handle, the backup sump pump will begin
pumping automatically. The backup system has
unique monitoring features that diagnose a
problem and sound an alarm. A light on the
display panel of the control unit will indicate the
cause of the alarm and the corrective action.
The two systems have been pre-assembled for
easy installation.

For added reliability, the float switches have, not
one, but two floats. Should one float fail to
operate, the second float will automatically
activate the pump.

The Pair of Pumps Combination Sump Pump
System includes:

• A 1/3 HP primary pump with a caged dual

float switch, and a blue piggyback controller
that plugs into the wall outlet

• A blue backup pump
• A gray control unit with a battery fluid

sensor, a dual float switch, battery cables,
and a 20-amp fuse

• A battery charger
• A battery cap with a hole to accommodate

the fluid sensor

• A battery box
• A rubber union
• A battery filler bottle for adding distilled

water to the battery

You will also need to supply:
• A Pro Series 2200 Standby Battery*
DO NOT use an automotive battery with this

system

DO NOT use a Pro Series 1000 battery with

this system. It will not run the pump as long
as the Pro Series 2200 battery

• A surge protector (recommended - backup

controller only)

• Six (6) quarts of 1.265 specific gravity

battery acid

* PHCC Pro Series standby batteries are

specifically designed to work with your
battery backup sump pump system.
Glentronics can not guarantee the
compatibility of other brands of batteries.
For optimal performance the use of a
PHCC Pro Series standby battery is
recommended.

For some installations you may need
additional items:

• 1-1/2” rigid PVC pipe to connect to the

existing plumbing

• A PVC pipe connector or a rubber union

• PVC pipe cleaner and cement

System Specifications

Power supply requirements.......115 volts, 60 Hz

AC pump pumping capacity..... 2770 GPH @ 10’

............................................. 46 GPM @ 10’

DC pump pumping capacity..... 1730 GPH @ 10’

............................................. 29 GPM @ 10’

Overall dimensions................. 11” W x 23¾” H

Page 2

Rubber
Union

Primary Pump Controller

Backup

Pump

Controller

Primary
Pump

Cable Tie

Battery Cap

Backup Pump

Float Switch

Backup

Pump

Battery Box

Battery

Filler

Bottle

Primary

Pump Float

Switch

Battery
Wires

Fluid Sensor