Date Logging:

There are two types of logging available with the FIC, Internal and PC logging. In

both modes of logging, the parameters that appear in the

“Gauges” window are logged.


Internal Logging:

The FIC contains an onboard 2 MB logger. The sampling rate and trip conditions

for the onboard logger are set in the

“FIC Logger” section of the “Setup” window. The

sampling rate can be set from 10mS to 1275mS. Sampling every 10mS will give four
minutes of data. Sampling every 1275mS will give 21 days of data. In order to start
internal logging, all the trip conditions must be met and the

“User Switch Input” must be

grounded. (Note: When using the

“User Switch Input” in the “Dual Calibration” mode,

the

” Logger Trigger” is always on by default.) To download data from the Internal

logger, go to Logger>Download FIC and save the file to the PC. Logged files are saved
as delimited text files.