AEM 30-1931 Universal Fuel Ignition Controller 8 Channel User Manual

Page 29

Advertising
background image

Page 29

PC Logging:

The FIC software allows you to log data to your PC while connected to the FIC.

The sampling rate and file size are determined by the available memory and processor
speed of the PC. To start PC logging, go to Logger>PC Logger Start. To stop PC
logging go to Logger> PC Logger Stop, give the file a name and save it. Logged files
are saved as delimited text files.


Dual Calibration:

The FIC has a

“Dual Calibration” mode, which allows the user to switch between

two maps with the flip of a switch. Some common uses for this are a race gas map, a
pump gas map, or a valet mode map. The

“User Switch Input” is used to switch

between maps. In order to use the

“Dual Calibration” feature of the FIC, the “Dual

Calibration

” mode must be selected in the “Setup” window, see Figure 28. When the

“User Switch Input” wire is not connected to ground, the FIC uses calibration “A”. When
the user input

switch wire is connected to ground, the FIC uses calibration “B”. To

upload/edit Calibration A, verify the user input wire is not connected to ground, the
follow the instructions

in the “Connecting to FIC” section. To upload/ edit Calibration B,

verify the

“User Switch Input” wire is connected to ground, the follow the instructions in

the “Connecting to FIC” section. (Note: The FIC will disconnect from the PC if you try to
switch calibrations while connected.)




























Advertising
This manual is related to the following products: