Pump install, Controller install – AEM 30-3352 V2 Water Methanol Nozzle and Controller Kit Multi Input Controller User Manual

Page 6

Advertising
background image

Page 6

Pump Install

Find a suitable location to mount the pump. The tank and pump must
be mounted in the same area. Pump may be mounted on exterior
of vehicle but should be mounted away from wheel wells or
other areas where it will come into direct contact with water or
road debris. Pump failures that have clearly been caused by
exposure to water/mud/debris will not be covered under
warranty.
This includes but is not limited to, the bed of a truck, and
the inside of the fender wells. Find a location where the pump will
remain dry.

The pump must be located in the same area as the tank and should be mounted at or below the
lowest fluid level height.

Take note of the direction of flow, indicated by the arrows on the pump body, when mounting the
pump.


Use four #8 sheet metal screws along with the 4 small washers or the #8-32 bolts and nylock
nuts to mount the pump. The pump can be mounted in any position horizontally or vertically.
Once the tank and pump are mounted, cut the appropriate length of tubing needed to connect
the outlet fitting on the tank to the inlet fitting on the pump. Make sure there are no sharp bends
in the tubing. Cut the tubing to length with a clean perpendicular slice using a sharp razor
blade, making sure the ends are clean and square. Push in the hose at the tank and pump to
install. Make sure they are pushed in all the way and check with a light tug on the hose. Secure
the hose to the chassis using sections of the supplied hose routing strip or with zip-ties.

Controller Install

The progressive controller is NOT waterproof and should NOT be mounted in the engine bay!
Find a convenient location for the controller

inside the driver’s compartment. The adjustment

knobs should remain in an accessible location but still remain protected from possible water
incursion. If you need to extend the wires to mount the controller use at least 16 AWG wire for
the pump and controller ground circuits and 18 AWG for the remainder. The controller contains

Advertising