Progressive Controller Installation

Pin #

Description

Wire**

Color

Connection

1

Pump Ground

16

AWG

Orange

Connect to ground (black) wire of pump.

2

LED -

20

AWG

Gray

Connect to ground (black) wire of external LED.

3

LED +

20

AWG

Violet

Connect to positive (red) wire of external LED.

4

Solenoid -

20

AWG

Brown/White

1.5A Low Side output. Connect to optional flow control
solenoid.

5

Boost Safe LS
Out

18

AWG

Green

1.7A Low Side output. Grounded when error condition
exists.

6

Pump Power

16

AWG

Pink

Connect to the positive (red) wire of pump.

7

Ground

16

AWG

Black

Main ground connection, connect directly to battery
ground.

8

Level Switch+

20

AWG

White

Connect to the white wire of the fluid tank level sensor*

9

Level Switch-

20

AWG

Brown

Connect to the black wire of the fluid tank level sensor*

10

Arm Switch +

20

AWG

Yellow

Arms injection system. Connect to a switched 12V
source.

11

External Signal

18

AWG

Blue

Connect to External Signal. (0-5V, injector duty, MAF
frequency)

12

Power 12V

16

AWG

Red

Main Power Connection, connect directly to positive
battery terminal.

*Note: If fluid tank is equipped with previous generation level sensor, identified by having two black wires, then

pins 8 (white) and 9 (brown) may be connected to either of the two black sensor wires. The polarity is
unimportant.

**Note: If you need to extend the wires to mount the controller use at least 16 AWG wire for the pump and

controller ground circuits and 18 AWG for the remainder.

External LED Install

Find a suitable location in the driver’s line of sight to mount the external LED. Mount the LED
and run the wires to the controller. The LED indicates the operation of the controller. If the
pump is off and there are no errors the LED will be off. If there are no errors and the pump is on
the LED intensity will vary with the pump speed. If there are any errors they will be indicated by
flashing the LED.