AEM 30-4110 Digital Wideband UEGO Gauge User Manual

Page 12

Advertising
background image

Page 12

10.0

11.0

12.0

13.0

14.0

15.0

16.0

17.0

18.0

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

Analog Voltage (V)

Air/Fuel Gasoline (AFR)

0.68

0.78

0.88

0.98

1.08

1.18

Lambda (

λ)

AFR Small Volt Range (P2)

AFR Autronic Emulation (P3)

AFR Nernst Emulation (P4)

AEM GAUGE Default (P0 & P1)

Figure 9. Calibration graph of available outputs


To change the calibrations, a precision flat head screwdriver is needed. Locate the small hole located on
the back of the AEM gauge, as shown below. (Figure 10)












Figure 10. Calibration position screw location


With the screwdriver, clock the rotary switch into the desired calibration position, referring to the diagram
below (Figure 10A), and watch the alphanumeric readout, which will display the new position when
entered.

P4

P3

P2

P1

P0

ROTARY SWITCH

Figure 10A. Calibration screw position settings


The calibration will not be changed until the rotary switch reaches the middle of the new position.