AEM 30-4110 Digital Wideband UEGO Gauge User Manual

Page 7

Advertising
background image

Page 7

Below (Table 2) is a list of AFR values that should be entered into the 02 Sensor #1(#2)
Cal Table if inputting the analog signal to an AEM EMS. These calibration table(s) are
found in the AEMPro software: Setup | Sensors | Oxygen Sensor | Oxygen Sensor
#1(#2)

02 Volts Lambda Gasoline AFR Methanol AFR Propane AFR Ethanol AFR CNG AFR

0.00

0.683

10.00 4.42 10.72 6.15

9.90

0.16

0.705

10.32 4.56 11.07 6.34

10.22

0.31

0.725

10.62 4.69 11.39 6.53

10.52

0.47

0.747

10.94 4.83 11.73 6.73

10.84

0.62

0.768

11.24 4.97 12.05 6.91

11.13

0.78

0.790

11.56 5.11 12.40 7.11

11.45

0.94

0.811

11.88 5.25 12.74 7.30

11.77

1.09

0.832

12.18 5.38 13.06 7.49

12.06

1.25

0.854

12.50 5.52 13.41 7.68

12.38

1.40

0.874

12.80 5.66 13.73 7.87

12.68

1.56

0.896

13.12 5.80 14.07 8.07

12.99

1.72

0.918

13.44 5.94 14.41 8.26

13.31

1.87

0.939

13.74 6.07 14.73 8.45

13.61

2.03

0.960

14.06 6.21 15.08 8.64

13.93

2.18

0.981

14.36 6.35 15.40 8.83

14.22

2.34

1.003

14.68 6.49 15.74 9.02

14.54

2.50

1.025

15.00 6.63 16.09 9.22

14.86

2.65

1.045

15.30 6.76 16.41 9.41

15.15

2.81

1.067

15.62 6.90 16.75 9.60

15.47

2.96

1.087

15.92 7.04 17.07 9.79

15.77

3.12

1.109

16.24 7.18 17.42 9.98

16.08

3.28

1.130

16.54 7.31 17.74

10.17

16.38

3.43

1.152

16.86 7.45 18.08

10.36

16.70

3.59

1.173

17.18 7.59 18.42

10.56

17.02

3.74

1.194

17.48 7.73 18.75

10.75

17.31

3.90

1.216

17.80 7.87 19.09

10.94

17.63

4.06

1.236

18.10 8.00 19.41

11.13

17.93

4.21

1.258

18.42 8.14 19.75

11.32

18.24

4.37

1.280

18.74 8.28 20.10

11.52

18.56

4.52

1.301

19.04 8.41 20.42

11.70

18.86

4.68

1.322

19.36 8.56 20.76

11.90

19.17

4.84

1.343

19.66 8.69 21.08

12.09

19.47

4.99

1.365

19.98 8.83 21.43

12.28

19.79

Table 2. EMS Calibration Tables, P0 mode

When connecting to AEM’s Series1 EMS, make sure to verify that the O2 #1 Gain option is set
so the voltage from the O2 #1 Volts parameter matches the voltage input at the EMS from the
O2 sensor. An easy way to do this is to disconnect the UEGO sensor from the UEGO gauge.
When in this state, the UEGO gauge will output 2.35 volts. You can then adjust the O2 #1 Gain
until the O2 #1 Volts display in AEMPro reads 2.35 volts.

When connecting to AEM’s Series2 EMS,

Advertising