Wire view of aem ems – AEM 30-6610 Series 2 Plug & Play EMS User Manual

Page 10

Advertising
background image

Page 10 of 14

Connection Diagram for EMS P/N 30-6610

PnP

Means the Plug and Play system comes with this configured for proper operation of this

device. Is still available for reassignment by the end user.

Available

Means the function is not currently allocated and is available for use

Dedicated

Means the location is fixed and cannot be changed

Pin

1995 Nissan 240SX S14 KA24DE (OBDI)

1995-1997 Nissan Sentra B14 SR20DE/GA16DE (x/c ’97 1.6L)

1995-1997 200SX B14 SR20DE/GA16DE (x/c ’97 1.6L)

1995-1996 Nissan Altima U13 KA24DE (x/c ’96 CA models)

1994-1996 Infiniti G20 P10 SR20DE

AEM EMS 30-6610

I/O

Notes

1

Ignition Signal

Coil 1

Output

PnP for Coil 1, 0-5V falling edge trigger

2

Ignition Check

EGT 3

Input

Available, Jumper set for 0-5V input

3

Tachometer Tachometer

(LS7)

Output

PnP for Tachometer

4

ECCS Self-Shutoff Relay Main

Relay

Output

Dedicated, EMS activates relay with switched GND

5

--- Idle

4

Output

Available, Ground/+12V, 1.5A max

6

--- Idle

3

Output

Available, Ground/+12V, 1.5A max

7

M/T 5

th

position switch (240SX & Altima Only)

ADCR14

Input

Available, 0-5V Input

8

Fuel Pump Relay

Low Side 11

Output

PnP for Fuel Pump

9

A/C Triple Pressure Switch (Altima & G20)/

A/C Hand Power Switch (240SX)

ADCR11 Input

Available, 0-5V Input

10

ECCS Ground

Power Ground

Input

Dedicated

11

---

High Side 1

Output

Available, +12V, 1.5A Max

12

A/C Triple-Pressure Switch (240SX, Sentra, 200SX Only)

CAN1L

Output

Dedicated, CAN1 low side

13

Cooling Fan High Relay (240SX & Altima Only)

Low Side 5

Output

PnP for Cooling Fan

14

Cooling Fan Low Relay

Low Side 3

Output

PnP for Cooling Fan

15

Air Conditioner Relay

Low Side 6

Output

PnP for A/C Compressor

16

--- Idle

2

Output

Available, Ground/+12V, 1.5A max

17

--- Idle

1

Output

Available, Ground/+12V, 1.5A max

18

Malfunction Indicator Light

Low Side 10

Output

Available, Switched ground, 1.5A max

19

ECCS Ground

Power Ground

Input

Dedicated

Wire View of AEM EMS