AEM Infinity Supported Applications - Toyota 1993-1997 Supra Turbo User Manual

Page 12

Advertising
background image

12

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware Reference

7100-XXXX-62
7101-XXXX-63

Function

Hardware Specification

Notes

C1-32

CANH_Aout

AEMNet CANH

Dedicated High Speed CAN
Transceiv er

Recommend twisted pair (one twist per 2")
with terminating resistor. Contact AEM f or
additional inf ormation.

C1-33

LowsideSwitch_1

Boost Control

Lowside switch, 4A max with
internal f ly back diode. Inductiv e
load should NOT hav e f ull time
power.

See Setup Wizard page Boost Control f or
options. Monitor BoostControl [%] channel
f or output state.

C1-34

Lowside Fuel Pump driv e

Fuel Pump

Lowside switch, 4A max, NO
internal f ly back diode.

Switched ground. Will prime f or 2 seconds
at key on and activ ate if RPM > 0.

C1-35

Analog_In_7

Throttle Position

Sensor

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU. See the Setup Wizard Set
Throttle Range page f or automatic min/max
calibration. Monitor the Throttle [%] channel.
Also DB1_TPSA [%] f or DBW applications.

C1-36

Analog_In_8

MAP Sensor

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU. See the Setup Wizard Set
Manif old Pressure page f or setup and
calibration. Monitor the MAP [kPa] channel.

C1-37

Analog_In_9

Fuel Pressure

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU. See the Setup Wizard
Fuel Pressure page f or setup and
calibration. Monitor the FuelPressure [psig]
channel.

C1-38

Analog_In_10

Baro Sensor

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU. See the Setup Wizard
Barometric Pressure page f or setup and
calibration. Monitor the BaroPress [kPa]
channel.

C1-39

Analog_In_11

Shif t Switch Input

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU.
See the 1D lookup table 'Shif tSwitch' f or
setup. Also assignable to multiple f unctions.
See Setup Wizard f or details.

C1-40

Analog_In_12

Mode Switch

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU.
See the 1D lookup table 'ModeSwitch' f or
input state.
A multi-position rotary switch such as AEM
P/N 30-2056 is recommended.
Also assignable to multiple f unctions. See
Setup Wizard f or details.

C1-41

+5V_Out_1

+5V Out

Regulated, f used +5V supply f or
sensor power

Analog sensor power

C1-42

+5V_Out_1

+5V Out

Regulated, f used +5V supply f or
sensor power

Analog sensor power

Advertising