3 hydraulic cylinder control – Lukas HP Cylinders User Manual

Page 15

Advertising
background image

15

7.2.2 Checking the pump unit

See separate operating instructions for the corresponding unit (or hand pump).

NOTE:

Before working on the pump unit or connecting/disconnecting hoses, always

make sure that the pump unit is switched off or disconnected from the supply

in the case of electric pumps, and that the control valves have been set to

depressurised recirculation.

7.3 Hydraulic cylinder control

Movement of the cylinder piston cannot be directly controlled by the cylinder. Extending

and retracting the cylinder must be controlled via a separate control unit or the connected

hydraulic unit.

7.2.1 Initial operation

Before commissioning and following repairs, the device must be de-aerated.

-

Connect the equipment to the hydraulic pump (see chapter “Connecting the

equipment”).

- Fully extend and retract the device several times without load.

NOTE:

We recommend that during the de-aeration, the attached unit for the hydraulic

supply should stand on a higher level than the cylinder.

The connections on the hydraulic cylinder should face upwards.

Advertising