7general steps prior to lifting – Lukas PO6 User Manual

Page 5

Advertising
background image

5

6.1.5

Power packs with 25 l oil container

The oil container is filled ex works with 15 l of hydraulic oil. If necessary,
the oil container can be filled up to a total volume of 24 l.
The filler plug for hydraulic oil (fig. 1) includes a dipstick with 2 marks:
1 = standard oil level 15 l ; 2 = max. oil level 24 l

6.2 Control valves

A number of control valve versions is available to meet different operator’s
requirements.

6.2.1

Drain valve "1E" for control of one single-acting jack

6.2.2

2-way distributor valve "2E" for control of two single-acting jacks

6.2.3

4/3-way valve "1D" for control of one double-acting jack

6.3

Hydraulic diagrams as per 6.2

7

General steps prior to lifting

7.1.1 Version "1E" :

Open hand wheel (1) on the drain valve (see fig. 2).

7.1.2 Version "2E" :

Open hand wheel (1) on the drain valve. Close hand wheels (3) on the
2-way distributor valve (see fig. 3).

7.1.3 Version "1D" :

Switch hand lever on the control valve to middle position (= marked O)
(see fig. 4).

7.1.4 Starting the motor
---->

Petrol engine: see separate operating manual.
Open the petrol cock and start the motor.

---->

Electric motor: The on/off switch of the motor is situated at the motor terminal box.
Position I:

the motor is started.

Position 0:

motor standstill.

Filler plug for
hydraulic oil

fig.1

Advertising