8option, 9maintenance – Lukas PO-4 User Manual

Page 7

Advertising
background image

7

8

Option

The equipment described below is not part of the standard scope of supply, but special equipment
which is to be purchased separately.

8.1 Pressure gauges

(item. 11 fig. 10)

8.1.1 For type PO4-NA

MEG 500
MEG 700

Remove screw plug G 1/4 in connection P above the connection board.
Screw in the pressure gauge with the stem.

8.1.2 For type PO4-N3 / PO4-N4

MEL 500
MEL 700

Insert the pressure gauge adapter directly into the connection bore A.

8.2 Remote control

The power pack with remote control is switched on by means of a pushbutton on the remote control
casing. The remote control is only put into operation when the 3-step switch (fig. 10, item 6) is set
to switch position II.
If you release the pushbutton the motor is stopped - inching mode -.

9

Maintenance

9.1 Oil level / Oil change

Check the hydraulic oil level after each operation and fill in new oil, if necessary.
Check the hydraulic power pack for possible leakages.
The cylinder must be retracted for filling in oil.
The oil level is correct, if the oil face is approx. 1 cm below the filling hole.

The 1st oil change should be made after approx. 100 operating hours. The cord packing Ø 6 mm
must be replaced with each oil change. The intervals between the further oil changes depend on
the operating hours and the pollution of the oil.

9.2 Oil for LUKAS hydraulic tools mineral oil DIN 51524 and others

A

-24 ... +30°C

HL 5

B

-18 ... +50°C

HLP 10

C

-8 ... +75°C

HLP 22

D

+5 ... +80°C

HLP 32

E

-8 ... +70°C

HF-E 15

biodegradable

recommended range of viscosity : 10...200 (mm

2

/s).

Range of oil temperature

Viscosity rating

Remarks