9.3 Preventive Maintenance

The oil tank must principally be cleaned with each oil change.
To clean the oil tank, the mounting screws on the oil tank cover must be loosened and the motor/
pump unit pulled out.

Attention
The tank must be cleaned by flushing with hydraulic oil.
Do not use textiles!

10 Service

Service may be carried out exclusively by the manufacturer of the device or by personnel trained
by the manufacturer and the authorized dealer.
Only genuine LUKAS spare parts may be used for repair works.
When carrying out maintenance or service works be sure to wear protective clothing (see safety
regulations), since rescue devices may be under pressure even in unoperated state.

10.1

Trouble Shooting

Malfunction
No delivery or only partial delivery from pump at no load.

Cause
Air in the suction area of the pump.

Remedy
Reduce the pressure at no load as far as possible - turn the adjusting screw of the pressure limiting
valve in anti-clockwise direction. Switchíng the pump on/off repeatedly supports the venting
process.

If the defects cannot be repaired, contact an authorized LUKAS dealer or the LUKAS service
department. The address: LUKAS Hydraulik GmbH, Weinstraße 39, 91058 Erlangen; P.O.B.
2560, 91013 Erlangen Germany; Service-Tel.: +49 / 91 31 / 6 98 - 3 38;
Fax: +49 / 91 31 / 69 83 53.

Description

Ref. no.

Operating press.

Dimensions

Weight

Remarks

PN (MPa)

(lxwxh) mm

kg

PO4-4-NA 500

84112/12

50

22

for

PO4-4-NA 700

84112/22

70

22

single-

PO4-4-NA 500F

84112/14

50

22,5

acting

PO4-4-NA 700F

84112/24

70

260x250x400

22,5

cylinders

PO4-4-N3/N4 500

84112/13

50

22,2

for

PO4-4-N3/N4 700

84112/23

70

22,2

double-

PO4-4-N3/N4 500F

84112/15

50

22,7

acting

PO4-4-N3/N4 700F

84112/25

70

22,7

cylinders

weight including oil filling.

11 Technical data

Advertising