Chapter 8 – Operation

44

TB100J – 0192517

Lower Controls

The lower controls override the upper controls. This

means that the lower controls can always be used to

operate the platform regardless of the position of the

upper control emergency stop button.

Boom, turntable and platform functions may be operated

from the lower controls. Boom elevation and extension

is limited when the rear axles are retracted. The lower

controls may be used for initial set up of the aerial plat-

form, and for testing and inspection.

Use the following procedure to operate boom, turntable

or platform functions using the lower controls.

1. On dual fuel machines, set the fuel switch to either

LPG or gasoline.

2. Open the shut-off valve on the tank if using LPG.

3. Pull the emergency stop button (refer to Figure 8.2)

outward. Place the control selector switch in the

lower control position.

4. Turn start key switch until the engine starts, then

release. The engine will not start if the controls

selector switch is left in the lower control position

for 30 seconds or longer before starting the engine.

The controls selector switch must be turned back to

off before the engine will start.

5. Let the engine warm to operating temperature.

6. Place the boom/axle switch in the axle position to

operate the rear axles and in the boom position to

operate the boom and turntable functions.

7. Hold the ground operation switch in the on posi-

tion while operating the boom and turntable control

toggle switches.

8. Hold the appropriate toggle switch in the desired

direction.

9. Release the function toggle switch to stop move-

ment.

10. Place the ground operation switch in the off position

when no functions are being operated.

The engine must be running and the switch used to turn

the system on must be at the same location that the en-

gine was started. For example, if the engine was started

from the lower controls, the warm-up switch at the lower

controls must be used for the system to operate.

Machine functions are not operational while using the

hydraulic warm-up system.

To operate the warm-up system:

1. Place the engine throttle in the slow position.

2. Place the controls selector switch in the lower control

position.

3. Place the warm-up switch in the on position.

4. After the hydraulic fluid reaches 50°F (10°C) as

indicated on the thermometer, place the warm-up

switch in the off position.

Manually Warming The Hydraulic System

The hydraulic oil may be warmed by toggling the Boom/

Axle switch to Axle. The boom must be in the stowed

position.

Caution

Not all hydraulic fluid is suitable to use in the hy-

draulic system. Some have poor lubricating char-

acteristics and can increase component wear. Only

use hydraulic fluid as recommended.

Use cold weather hydraulic oil as recommended in the

machine General Specifications in temperatures of 10°F

(-13°C) or below.

Preparing for Operation

Use the following procedure to prepare the aerial plat-

form for operation.

1. Perform a prestart inspection as described in Chap-

ter 7.

2. Place the battery disconnect switch in the on posi-

tion.

3. Close and latch the doors.

4. Before painting or sandblasting make sure the

sandblast protection kit and the platform control

cover are properly installed. These options, when

used properly will protect the control placards and

cylinder rods from paint overspray and abrasion

while sandblasting.

Advertising