Chapter 10 – Emergency Operation

56

TB100J – 0192517

Figure 10.4 – Platform Foot Switch

4. Hold the appropriate function toggle switch in the

desired direction.

5. Hold the engine/emergency power switch in the

emergency power position.

Electric Emergency Bleed Down System

The main boom can be lowered in an emergency using

the electric emergency bleed down system. The electric

emergency bleed down system is located on both the

upper controls and on the junction box located on the

left side of the machine. Use this method if the engine

will not start and the emergency power system will not

work.

Use the following procedure to lower the boom using

the electric emergency bleed down system. This proce-

dure can be used from the upper or lower bleed down

switches.

1. Turn key to the off position.

2. Pull the emergency stop button out.

Danger

The aerial platform can tip over if it becomes un-

stable. Death or serious injury can result from a tip-

over accident. When using the bleed down systems

the boom must retract and lower at the same time.

If the boom does not retract while lowering, cease

operations immediately.

3. Toggle and hold the emergency bleed down switch-

es on both sides of the panel simultaneously (refer

to Figure 10.5) Hold the switches in the up position

to lower and retract the boom.

Figure 10.5 – Emergency Bleed Down Switches

Figure 10.3 – Upper Controls

Front

Master Start Switch

Top

Emergency

Stop Button

Engine/Emergency

Power

Emergency Bleed

Down Switch

Emergency Bleed

Down Switch

Platform Foot

Switch