Electricl troubleshooting chart -2 – JLG 3246E2 Service Manual User Manual

Page 68

Advertising
background image

SECTION 3 - TROUBLESHOOTING

3-2

– JLG Sizzor –

3120855

Table 3-1. Electricl Troubleshooting Chart

TROUBLE

PROBABLE CAUSE

REMEDY

All machine functions do not operate

Emergency stop switch not activated

Activate Emergency stop switch

Joystick not in neutral position

Release joystick, then select function

Platform cable not connected to platform box

or at base

Re-connect cable to platform box and check

wiring at base

Battery voltage out of range

If battery cahrger is plugged in

Check voltage with VOM. Unplug battery

charger

Battery voltage too low

Check voltage with VOM. Plug in battery

charger

Line contactor open circuit

Loose wiring connections on line contactor or

at harness connection

Check wire terminations on line contactor

and harness connection at base. Tighten

connections as necessary

Open coil on line contactor

Clean corrosion from line contactor

Replace line contactor

Faulty wiring at base

Repair or replace wiring as necessary

Line contactor welded.

Replace the line contactor

Line contactor or other driver short circuit or

tripped

Point A short circuit

Motor stalled

Determine cause. Repair or replace motor as

necessary

Motor open circuit

Faulty motor

Replace motor

No drive function when platform fully low-
ered. Lift function okay

Malfunctioning limit switch

Use VOM to verify limit switch inputs. Adjust

or repair malfunctioing limit switch

No drive function when platform elevated.
Lift function okay

Malfunctioning limit switch

Use VOM to verify limit switch inputs. Adjust

or repair malfunctioing limit switch

Platform above drive cutout height

Lower platform below drive cutout height

Machine cannot lift down. Lift up function
okay

Loose wiring on lift cylinder (s) at holding

valve

Repair wiring on lift cylinder (s) at holding

valve