Electrical System

9-46

G10-55A, G12-55A

245

647

4

Amber

Fan Clutch Output

Device Driver

Fan Control Circuit - Voltage Below Normal, or
Shorted to Low Source

249

171

3

Amber

Ambient Air

Temperature

Ambient Air Temperature Sensor Circuit -
Voltage Above Normal, or Shorted to High
Source

256

171

4

Amber

Ambient Air

Temperature

Ambient Air Temperature Sensor Circuit -
Voltage Below Normal, or Shorted to Low
Source

261

174

16

Amber

Fuel Temperature

Engine Fuel Temperature - Data Valid but
Above Normal Operational Range - Moderately
Severe Level

263

174

3

Amber

Fuel Temperature

AEB15.60 Page 149 of 157 Engine Fuel
Temperature Sensor 1 Circuit - Voltage Above
Normal, or Shorted to High Source

265

174

4

Amber

Fuel Temperature

Engine Fuel Temperature Sensor 1 Circuit -
Voltage Below Normal, or Shorted to Low
Source

268

94

2

Amber

Fuel Delivery

Pressure

Fuel Pressure Sensor Circuit - Data Erratic,
Intermittent, or Incorrect

271

1347

4

Amber

Fuel Pump

Pressurizing

Assembly #1

High Fuel Pressure Solenoid Valve Circuit -
Voltage Below Normal, or Shorted to Low
Source

272

1347

3

Amber

Fuel Pump

Pressurizing

Assembly #1

High Fuel Pressure Solenoid Valve Circuit -
Voltage Above Normal, or Shorted to High
Source

281

1347

7

Amber

Fuel Pump

Pressurizing

Assembly #1

High Fuel Pressure Solenoid Valve #1 -
Mechanical System Not Responding Properly
or Out of Adjustment

284

1043

4

Amber

Internal Sensor

Voltage Supply

Engine Speed/Position Sensor (Crankshaft)
Supply Voltage Circuit - Voltage Below Normal,
or Shorted to Low Source

285

639

9

Amber

SAE J1939 Datalink

SAE J1939 Multiplexing PGN Timeout Error -
Abnormal Update Rate

286

639

13

Amber

SAE J1939 Datalink

SAE J1939 Multiplexing Configuration Error-
Out of Calibration

287 91

19

Red

Accelerator

Pedal

Position

SAE J1939 Multiplexing Accelerator Pedal or
Lever Sensor System Error - Received Network
Data In Error

288

974

19

Red

Remote Accelerator

SAE J1939 Multiplexing Remote Accelerator
Pedal or Lever Data Error - Received Network
Data In Error

Fault

Codes

SPN

Codes

FMI

Codes

Lamp
Color

SPN Description

Cummins Description

Advertising