JLG G12-55A Service Manual User Manual

Page 191

Advertising
background image

9-49

G10-55A, G12-55A

Electrical System

442

168

16

Amber

Electrical Potential

(Voltage)

Battery #1 Voltage High - Data Valid but Above
Normal Operational Range - Moderately Severe
Level

449

157

0

Red

Injector Metering

Rail 1 Pressure

Fuel Pressure High - Data Valid but Above
Normal Operational Range - Moderately Severe
Level

451

157

3

Amber

Injector Metering

Rail 1 Pressure

Injector Metering Rail #1 Pressure Sensor
Circuit - Voltage Above Normal, or Shorted to
High Source

452

157

4

Amber

Injector Metering

Rail 1 Pressure

Injector Metering Rail #1 Pressure Sensor
Circuit - Voltage Below Normal, or Shorted to
Low Source

488

105

16

Amber

Intake Manifold

Intake Manifold 1 Temperature - Data Valid but
Above Normal Operational Range - Moderately
Severe Level

489

191

18

Amber

Transmission Output

Shaft Speed

Transmission Output Shaft Speed - Data Valid
but Below Normal Operational Range -
Moderately Severe Level

497

1377

2

Amber

Switch Circuit

AEB15.60 Page 151 of 157 Multiple Unit
Synchronization Switch Circuit - Data Erratic,
Intermittent, or Incorrect

523

611

2

Amber

System Diagnostic

code #1

OEM Intermediate (PTO) Speed switch
Validation - Data Erratic, Intermittent, or
Incorrect

527

702

3

Amber

Circuit - Voltage

Auxiliary Input/Output 2 Circuit - Voltage Above
Normal, or Shorted to High Source

528

93

2

Amber

Switch - Data

Auxiliary Alternate Torque Validation Switch -
Data Erratic, Intermittent, or Incorrect

529

703

3

Amber

Circuit - Voltage

Auxiliary Input/Output 3 Circuit - Voltage Above
Normal, or Shorted to High Source

546

94

3

Amber

Fuel Delivery

Pressure

Fuel Delivery Pressure Sensor Circuit - Voltage
Above Normal, or Shorted to High Source

547

94

4

Amber

Fuel Delivery

Pressure

Fuel Delivery Pressure Sensor Circuit - Voltage
Below Normal, or Shorted to Low Source

551

558

4

Amber

Accelerator Pedal

Low Idle Switch

Accelerator Pedal or Lever Idle Validation
Circuit - Voltage Below Normal, or Shorted to
Low Source

553

157

16

Amber

Injector Metering

Rail 1 Pressure

Injector Metering Rail #1 Pressure High - Data
Valid but Above Normal Operational Range -
Moderately Severe Level

Fault

Codes

SPN

Codes

FMI

Codes

Lamp