JLG G12-55A Service Manual User Manual

Page 192

Advertising
background image

Electrical System

9-50

G10-55A, G12-55A

554

157

2

Amber

Injector Metering

Rail 1 Pressure

Fuel Pressure Sensor Error - Data Erratic,
Intermittent, or Incorrect

559

157

18

Amber

Injector Metering

Rail 1 Pressure

Injector Metering Rail #1 Pressure Low - Data
Valid but Below Normal Operational Range -
Moderately Severe Level

584

677

3

Amber

Starter Solenoid

Lockout Relay Driver

Circuit

Starter Relay Circuit - Voltage Above Normal, or
Shorted to High Source

585

677

4

Amber

Starter Solenoid

Lockout Relay Driver

Circuit

Starter Relay Circuit - Voltage Below Normal, or
Shorted to Low Source

595

103

16

Amber

Turbocharger 1

Speed

Turbocharger #1 Speed High - Data Valid but
Above Normal Operational Range - Moderately
Severe Level

596

167

16

Amber

Alternate Potential

(voltage)

Electrical Charging System Voltage High - Data
Valid but Above Normal Operational Range -
Moderately Severe Level

597

167

18

Amber

Alternate Potential

(voltage)

Electrical Charging System Voltage Low - Data
Valid but Below Normal Operational Range -
Moderately Severe Level

598

167

1

Red

Alternate Potential

(voltage)

Electrical Charging System Voltage Low - Data
Valid but Below Normal Operational Range -
Most Severe Level

599

640

14

Red

Engine External

Protection Input

Auxiliary Commanded Dual Output Shutdown -
Special Instructions

649

1378

31

Maint

Engine Oil Change

Interval

Change Lubricating Oil and Filter - Condition
Exists

687

103

18

Amber

Turbocharger 1

Speed

Turbocharger #1 Speed Low - Data Valid but
Below Normal Operational Range - Moderately
Severe Level

689

190

2

Amber

Engine Speed

Primary Engine Speed Sensor Error - Data
Erratic, Intermittent, or Incorrect

691

1172

3

Amber

Turbocharger #1

Compressor Inlet

Temperature

Turbocharger #1 Compressor Inlet Temperature
Sensor Circuit - Voltage Above Normal, or
Shorted to High Source

692

1172

4

Amber

Turbocharger #1

Compressor Inlet

Temperature

Turbocharger #1 Compressor Inlet Temperature
Sensor Circuit - Voltage Below Normal, or
Shorted to Low Source

697

1136

3

Amber

Sensor Circuit -

Voltage

ECM Internal Temperature Sensor Circuit -
Voltage Above Normal, or Shorted to High
Source

Fault

Codes

SPN

Codes

FMI

Codes

Lamp
Color

SPN Description

Cummins Description

Advertising