JLG 601S Operator Manual User Manual

Page 43

Advertising
background image

SECTION 3 - MACHINE CONTROLS AND INDICATORS

3121218

– JLG Lift –

3-11

1. Tilt Alarm Warning Light. (Orange)

This orange illuminator indicates that the chassis is on a
slope (over 5 degrees). If illuminated when boom is
raised or extended, retract and lower to below horizontal
then reposition machine so that it is level before extend-
ing boom or raising boom above horizontal. If the boom
is above horizontal and the machine is on a 5 degree
slope, an alarm will sound and CREEP is automatically
activated.

2. Platform Overload (If equipped)

Indicates the platform has been overloaded.

3. Capacity Indicator

When illuminated (Red), the light indicates the maximum
platform capacity for the current position of the platform.
1000 pounds (450 kg) capacity is permitted at restricted
platform positions (shorter boom lengths and higher
boom angles), and 500 pounds (230 kg) is the maxi-
mum capacity in all other positions.

4. Enable Indicator/Footswitch

To operate any function, the footswitch must be
depressed and the function selected within seven sec-
onds. The enable indicator shows that the controls are
enabled. If a function is not selected within seven sec-
onds, or if a seven second lapse between ending one
function and beginning the next function, the enable
light will go out and the footswitch must be released and
depressed again to enable the controls.

Releasing the footswitch removes power from all con-
trols and applies the drive brakes.

TO AVOID SERIOUS INJURY, DO NOT REMOVE, MODIFY OR DISABLE
THE FOOTSWITCH BY BLOCKING OR ANY OTHER MEANS.

FOOTSWITCH MUST BE ADJUSTED IF FUNCTIONS ACTIVATE WHEN
SWITCH ONLY OPERATES WITHIN LAST 1/4" OF TRAVEL, TOP OR BOT-
TOM.

Advertising