SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

6-16

– JLG Lift –

3121218

8. Suction Strainers (in tank)

Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation, remove
and clean at time of hydraulic oil change.

9. Oil Change w/Filter - Ford LRG425

Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 4.5 Quarts
Lube - EO
Interval - 3 Months or 150 hours of operation
Comments - Check level daily/Change in accordance with
engine manual.

REMOVE FILL CAP PLATE FROM
TANK TO GAIN ACCESS TO
STRAINERS