SERVICE (cont.)

Electronic Controls (cont.)

Liquid Level Control Test Procedure

1. Disconnect the dispenser from the power source.
2. Check the voltage across terminals 3 & 4 of the

electronic control assembly with a voltmeter. Con-
nect the dispenser to the power source. The indi-
cation must be:
a.) 100 to 120 volts ac for 100 to 120 volt models
or
b.) 200 to 240 volts ac for 200 to 240 volt models
or
c.) 230 volts ac for 230 volt models.

3. Disconnect the dispenser from the power source.

If voltage was present as described, proceed to #4.
If voltage was not present as described, refer to
the Wiring Diagrams and check the dispenser wir-
ing harness.

4. Remove the pink wire from terminal 5 of the elec-

tronic control assembly.

5. Check the voltage across terminals 1 & 4 of the

electronic control assembly with a voltmeter. Con-
nect the dispenser to the power source. The indi-
cation must be:
a.) 100 to 120 volts ac for 100 to 120 voltmodels
or
b.) 200 to 240 volts ac for 200 to 240 volt models
or
c.) 230 volts ac for 230 volt models
after a delay of approximately 5 seconds.

6. Disconnect the dispenser from the power source.

If voltage was present as described, the liquid level
control of the system is operating properly, proceed to
#7.
If voltage was not present as described, replace the
electronic control assembly and the temperature sen-
sor in the tank lid.

NOTE - Each electronic control assembly is calibrated
to a temperature sensor. Both components MUST be
replaced as a set.

Temperature Control Flow Charts

Limit Thermostat OK

?

Red Light On

Constantly

?

Measure Voltage

At Tank Heater

No

No

Yes

Yes

Yes

No

No

H5X THERMOSTAT

PROBLEM: Water Not Hot Enough

Replace Limit Thermostat

Voltage Present

?

Voltage Present

?

Yes

Measure Voltage

At Tank Heater

Replace Tank Heater

Replace Control Assembly

Replace Triac

Reinstall Original

Control Assembly

Check For Split Tank Heater

Recheck Water Temperature

Replace Steam Sensor

Red Light On

Constantly

?

Replace Control Assembly

Yes

No

Recheck Water Temperature

Jumper JP1

In Boil Position

?

Yes

No

Reposition Jumper

Limit Thermostat OK

?

Red Light On

Constantly

?

Measure Voltage

At Tank Heater

No

No

Yes

Yes

Yes

No

No

H5E THERMOSTAT

PROBLEM: Water Not Hot Enough

Replace Limit Thermostat

Voltage Present

?

Voltage Present

?

Yes

Measure Voltage

At Tank Heater

Replace Tank Heater

Replace Control Assembly

Replace Triac

Reinstall Original

Control Assembly

Check For Split Tank Heater

Recheck Water Temperature

Turn Temperature

Adjustment Screw

Clockwise Contiuously

Red Light On

?

Replace Control Assembly

Yes

No

Adjust For Correct

Water Temperature

10420 091902