Electrical requirements, Initial set-up – Bunn H5X User Manual

Page 4

Advertising
background image

4

ELECTRICAL REQUIREMENTS

CAUTION - The dispenser must be disconnected from the power source until specified in

Initial Set-Up.

This dispenser requires 2-wire, grounded service rated 120, 208, or 240 volts ac, 20 amp, single phase.

(Refer to the dispenser’s dataplate for exact voltage requirement.)

Electrical Hook-Up

CAUTION – Improper electrical installation will damage electronic components.

1.

An electrician must provide electrical service as specified.

2.

Using a voltmeter, check the voltage and color coding of each conductor at
the electrical source.

3.

Remove the upper and lower rear panels. Place the tank heater switch on the
electronic control assembly in the “OFF” position.

4.

Install a strain relief and the proper electrical wiring to the terminal block.

5.

Connect the dispenser to the power source and verify the voltage at the termi-
nal block before proceeding. Reinstall both rear panels.

6.

If plumbing is to be hooked-up later be sure the dispenser is disconnected from
the power source. If Plumbing has been hooked-up, the dispenser is ready for

Initial Set-Up

.

208 or 240V.A.C.

L2 RED

L1 BLACK

120V.A.C.

NEUTRAL

WHITE

L1 BLACK

Advertising