Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few minutes
to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.

1.Halogen light push-button

6. Maximum blower speed icon

INSTEON™ Master Link Mode push-button

7. Particulates sensor icon

2. Blower push-button

8. Blower speed level/

3. Enable/Disable functions push-button/

INSTEON™ state icon

INSTEON™ Erase Link push-button

9. Air refresh function icon

4. Grease filter reset push-button/

10. Blower speed icon

INSTEON™ Link Mode push-button

11. INSTEON™ icon

5 Grease filters maintenance icon

Cooktop Lighting (Halogen)
• The halogen lighting is controlled by the light push-button (item 1 on illustration above). Push once to turn ON the lights, and push

a second time to turn the lights ON to a brighter level. If the lights are at the highest level, pressing another time will set them to
the lowest intensity.

• Press on the push-button and maintain for 1 second to turn Off the lights and set the memorized intensity. When turned on, the

halogen bulbs will light cooktop at the previous setting.

• Use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).

Blower

• The blower is controlled by the blower push-button (item 2 on illustration above). Push once to turn ON the blower, and push a

second time to set the blower speed to a higher level. If the blower speed is on maximum level, pressing another time will turn the
blower to the lowest speed.

• When power level 1 is activated from OFF, 100% of power level is activated during 0.3 second acting as a “kick-start”.
• Press on the push-button and maintain for 1 second to turn Off the blower and set the memorized speed. When turned ON, the

blower will operate at the previous setting.

• When the blower is ON, the speed level is shown by the center icon (item 8 on illustration above) while the icon 10 appears (the

speed of the rotational movement is proportional to the blower speed).

• When the blower is on the higher speed, the icon 10 shuts off and the icon 6 appears with “max” (the symbol has a rotational

movement).

Functions
Pressing on Enable/Disable functions push-button (item 3 on illustration above) allows to control Particulate Sensor and Air Refresh
hood functions.

Particulates Sensor
• To activate the particulate sensor function, press on Enable/Disable functions push-button (item 3 on illustration above), the

particulates sensor icon (item 7 on illustration above) will appear.

• When the sensor is activated, the blower turns ON automatically when some particulates, vapors or smokes caused by cooking

process, or abnormal gas emissions in the environment are detected. The blower speed is automatically set depending on the
particulates amount and the sensibility settings of the particulates sensor. See next paragraph.

• To stop the particulates sensor function, press on Enable/Disable functions push-button until particulates sensor icon turns off.
Particulates sensor sensibility settings
• Press on Enable/Disable functions push-button (item 3 on illustration above) to activate the particulate sensor function, this will

light up the particulates sensor icon (item 7 on illustration above). Then, press and maintain for 2 seconds the Enable/Disable
functions push-button : the sensor sensivity level will appear on center icon (item 8 on illustration above).

• Press again on this push-button to change the sensor sentivity level (from 0 [minimum sensitivity] up to 9 [maximum sensitivity]).
• Press on the grease filter reset push button (item 4 on the illustration above) to confirm (or is confirmed automatically after

5 seconds).

Air Refresh
• To activate the air refresh function, press on Enable/Disable functions push-button (item 3 on illustration above), the air refresh

function icon (item 9 on illustration above) will appear.

• To stop the air refresh function, press on Enable/Disable functions push-button until air refresh icon turns off.
• Air refresh function activates only when blower is OFF. When activated, the blower hood recycles the air in the environment in

perfect silence, starting every 50 minutes (for 10 minutes, on first speed).