Install blower housing, Install transition to rough-in plate, Install the rough-in plate in the blower housing – Best IP29M Series User Manual

Page 9: Secure blower housing to brackets, Interior blower only)

Advertising
background image

- 9 -

HD0231

I

NSTALLATION WITH

DRY WALL TRIM

ATDIP S

ERIES

8. INSTALL BLOWER HOUSING

Use both screws (A) previously removed in step 4 to assemble the blower housing to the mounting brackets. For installation with decorative
flue cover AEIWP Series only, place 4 nuts (B) (from flue cover parts bag) on the pem studs, leaving 1/4” for the hood installation. The
blower housing must be installed in such a way that its label (C) will be on the same side as the hood control side. See illustrations below.

HD0230

I

NSTALLATION WITH

DECORATIVE FLUE COVER

AEIWP S

ERIES

A

B

B

Model 423, 424, 427 453, or 454
Attach transition (if required) to blower rough-in plate.
Use metal duct tape to make all joints secure and air-tight.

NOTE:

Model P6 blower plate connects directly to 7’’ round ductwork without a transition.

HO0086

10.INSTALL TRANSITION TO ROUGH-IN PLATE

(INTERIOR BLOWER ONLY)

11.INSTALL THE ROUGH-IN PLATE IN THE BLOWER HOUSING

Run power cable to installation location. Refer to the instructions included with
the selected blower/rough-in kit (sold separately) for details on installing the
rough-in plate. Install the rough-in plate so that the wiring box is located on the
right side when facing the hood, as specified on the blower housing label.
Connect transition or rough-in plate to ductwork. Use metal duct tape to make
all joints secure and air-tight.

HD0232

C

C

W

IRING COVER

A

From the inside, secure the blower housing to mounting brackets, using 2 no. 8 x 3/8”
screws per side.
Screws must be installed in embossed sections, see details beside.

HO0100

9. SECURE BLOWER HOUSING TO BRACKETS

R

ETAINING SCREWS LOCATION