Build the framework, Aeiwp s, Atdip s – Best IP29M Series User Manual

Page 8: Warning

Advertising
background image

- 8 -

In the ceiling material, cut-out a 28¾” x 12½” max.
opening over the installation location. Install two
supporting studs inside the cut-out at dimensions
shown beside.

7. BUILD THE FRAMEWORK

7.1 S

UGGESTED

F

RAMEWORK FOR

I

NSTALLATION WITH

D

ECORATIVE

F

LUE

C

OVER

AEIWP S

ERIES

7.2 S

UGGESTED

F

RAMEWORK FOR

I

NSTALLATION WITH

D

RYWALL

T

RIM

ATDIP S

ERIES

HD0235

27¼”

C

C

L

C

L

HD0237

F

RAMEWORK

54’’ H

OOD

F

RAMEWORK

42’’ H

OOD

WARNING

When building framework, always follow all applicable construction codes and standards.

!

The framework must be sized to support the total weight of the hood. Refer to the table below for total weight of the hood, according to the
type of blower chosen.

H

OOD

W

IDTH

WITH

P6

INTERIOR BLOWER

WITH

P12

INTERIOR BLOWER

WITH

I

N

-

LINE OR

E

XT

.

BLOWERS

(

ROUGH

-

IN PLATE ONLY

)

42”

71

LB

84

LB

52

LB

54”

86

LB

99

LB

67

LB

28½”

12½”

max.

27”

C

L

28¾”

HD0227A

C

L

12 /

8

5

Studs flush

with ceiling material

ceiling

material

ceiling

material

S

UPPORTING

S

TUDS

Using provided wood screws no. 10 x 1.5” and washers, assemble both mounting brackets
(included with the optional decorative flue cover) to the framework. See illustration beside.

HD0228A

Below is the suggested framework for both 42” and 54” width hoods to be installed with drywall trim ATDIP Series. Refer to the table
and illustrations below for the dimensions according to the hood width. Using provided wood screws no. 10 x 1.5” and washers,
assemble both mounting brackets (included with the optional drywall trim) to the framework.

H

OOD WIDTH

A

WITH

5/8”

DRYWALL

A

WITH

1/2”

DRYWALL

B

WITH

5/8”

DRYWALL

B

WITH

1/2”

DRYWALL

C

42”

11

5

8

11

7

8

28

5

8

28

7

8

10”

MINIMUM

54”

11

5

8

11

7

8

40

5

8

40

7

8

10”

MINIMUM

F

RAMEWORK

T

OP

V

IEW

Advertising